BVCRB - ACETIC ACID, GLACIAL

  • MSDS: BVCRB
  • Manufacturer: GENERAL CHEMICAL CORP
  • Product Name: ACETIC ACID, GLACIAL
  • National Stock Number: 6810-00N049236
Product Identification

Product ID:ACETIC ACID, GLACIAL
MSDS Date:10/01/1989
FSC:6810
NIIN:00N049236
MSDS Number: BVCRB

Responsible Party
GENERAL CHEMICAL CORP
90 EAST HALSEY ROAD
PARSIPPANY, NJ 07054
US

Emergency Phone: 201-515-1840

Info Phone: 201-515-1840

Cage: 0AU44

Contractor
GENERAL CHEMICAL CORPORATION
PARSIPPANY, NJ 07054 US

Telephone: 973-515-1840

Cage: 0AU44

Ingredients

W/METALS TO PRDCE HYDROGEN GAS. CAUSES SEV BURNS. MAY

RTECS: 9999999ZZ


NIOSH/MSHA APPRVD GAS MASKS W/ORG VAP

RTECS: 9999999ZZ


MOUNTED FAN/BLOWER. MATL SHOULD PREF BE USED IN AN

RTECS: 9999999ZZ


DUCTS SHOULD BE ACID-RESISTANT.

RTECS: 9999999ZZ


LGTH FACESHIELD .

RTECS: 9999999ZZ


DEPEND ON CNDTNS. ANSI APPVD EYEWASH

RTECS: 9999999ZZ


PROVIDE PROTECTIVE CARRIERS FOR HANDLING MATERIAL IN

RTECS: 9999999ZZ


ACETIC ACID

CAS: 64-19-7

RTECS: AF1225000

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM;15 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


SODIUM BICARBONATE. LG SPILLS SHOULD BE CNTND &

RTECS: 9999999ZZ


EVENTUAL WASTE DISPOSAL.

RTECS: 9999999ZZ


MENTIONED REGS, WASTE MATL CAN BE

RTECS: 9999999ZZ


BURNING); OR NEUTRALIZED WASTE DISP OF IN AN APPRVD

RTECS: 9999999ZZ


SOLIDIFICATION. IF FROZEN, THAW BY CAREFULLY

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT)3310 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: VAP CAUSES IRRIT OF EYES, NOSE
& THROAT; CAN AFFECT RESP RESPONSE, CAUSE COUGHING & CHEST PAINS.
INGEST: SEV PAIN IN MOUTH, GULLET, STOM; POSS CIRCULATORY COLLAPSE,
UREMIA & DEATH(HUMAN). SKIN : CONC SOLN CAUSES SEV BURNS IF NOT
PROMPTLY WASHED OFF. VAP MAY BLACKEN SKIN & EXPOSED TEETH. DILUTE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: SOLN MAY CAUSE DERM IN SOME SENSITIVE
INDIVIDUALS. EYES: CAUSES SEV BURNS. MAY CAUSE PERM CORNEAL INJURY,
WHICH MAY BE FOLLOWED BY BLINDNESS. HIGH VAP CONC MAY RSLT IN CONJ.
CHRONIC: IRRIT O F RESP TRACT, CHRONIC BRONCH, EROSION OF TEETH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:CALL A PHYS @ ONCE. INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG,
GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. IF BRTHG IS DFCLT, GIVE OXYGEN
IF QUALIFIED OPERATOR IS AVAIL. INGEST: DO NOT INDUCE VOMIT. GIVE
TAP WATER, MILK (2-3 GLASSES), MILK OF MAGNESIA/EGG WHITES BEATEN
W/WATER. NEVER GIVE ANYTHING BY MOUTH TO AN UNCON PERSON. SKIN:
IMMED FLUSH W/PLENTY OF WATER FOR 15 MIN, WHILE REMOVING CONTAMD
(SUPDAT)

Fire Fighting

Flash Point Method:CC
Flash Point:104F,40C
Lower Limits:5.4%
Upper Limits:16%
Extinguishing Media:WATER SPRAY, FOAM, CO*2/DRY CHEMICAL. WATER IN A
SOLID STREAM WILL SCATTER AND SPREAD FIRE. USE WATER SPRAY.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP . USE
WATER SPRAY TO COOL CONTRS EXPOSED TO FIRE & TO PROTECT THOSE
INVOLVED IN FIRE-FIGHTING. WATER MAY (SUPDAT)
Unusual Fire/Explosion Hazard:GIVES OFF FLAMM VAP ABOVE ITS FL PT
(104F). IT IS DANGEROUS IN CONT W/CHROMIC ACID, SODIUM PEROXIDE,
NITRIC ACID OR OTHER OXIDIZING MATERIALS.

Accidental Release

Spill Release Procedures:PROVIDE ADEQ VENT. CLEAN-UP PERS SHOULD WEAR
NIOSH/MSHA APPRVD SCBA & PERSONAL PROT EQUIP TO PVNT LIQ CONT. USE
WATER SPRAY TO DISPENSE VAPS & PROTECT INVOLVED PERS & TO REDUCE
FLAMM. ELIM IGNIT SOURC ES. SM SPILLS CAN BE NEUT W/SODA ASH/ (ING
2)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID BRTHG VAPS.AVOID LIQ/VAP CONT
W/EYES, SKIN/CLTHG. USE W/ADEQ VENT. KEEP AWAY FROM HEAT, SPARKS &
OPEN FLAME. WEAR PERSONAL PROT EQUIP AS NEEDED.
Other Precautions:STORE IN CLSD CONTRS IN A WELL-VENTD AREA.
OUTDOORS/DETACHED STOR IS PREFERRED. KEEP AWAY FROM OXIDIZING
AGENTS & COMBUST MATLS. KEEP ABOVE ITS FREEZING POINT (62F) TO
AVOID RUPTURE OF CARBOYS & GLASS CONTRS DUE TO EXPANSION UPON (ING
6)

Exposure Controls

Respiratory Protection:WHERE VAPS ARE BELOW 500 PPM, USE A NIOSH/MSHA
APPRVD CHEM CARTRIDGE, ORG VAP RESP W/FULL FACEPIECE/A SCBA W/FULL
FACEPIECE. VAPS TO 1000 PPM REQ AN NIOSH/MSHA APPRVD AIR-SUPPLIED
RESP W/FULL FACEPIEC E. ESCAPE CNDTNS CALL FOR (ING 8)
Ventilation:PROVIDE ADEQ EXHST VENT TO MEETL TLV/TWA REQUIREMENTS. LOC
EXHST-FROM FLOOR & LOW SPACES. MECH(GEN): FLOOR- (ING 9)
Protective Gloves:IMPERVIOUS GLOVES (RUBB/NEOPRENE).
Eye Protection:ANSI APPRVD CHEM WORKS GOGG/FULL(ING 11)
Other Protective Equipment:RUBB APRON. IN CASE OF LEAK, SPILL/EMER
SITUATIONS W/POSS OF CONT W/MATL, ADD FULL IMPERVIOUS CLTHG. RUBB
BOOTS,(ING 12)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: BE USED TO DILUTE SPILLED MATL, TO REDUCE FLAMM &
DISSIPATE IRRITATING VAPS ENVOLVING FROM FIRE. FIRST AID PROC:
CLTHG. WASH CLTHG BEFORE REUSE. EYES: IMMED FLUSH W/PLENTY OF WATER
FO R @ LST 15 MIN. IF IRRIT PERSISTS, FLUSH AN ADDNL 15 MIN. SEEK
MED ASSIST FOR INHAL, INGEST & IRRIT.

Chemical Properties

Boiling Pt:B.P. Text:244F,118C
Melt/Freeze Pt:M.P/F.P Text:62.1F,16.7C
Vapor Pres:11.4@20C
Vapor Density:2.07
Spec Gravity:1.05(H*2O=1)
pH:2.4
Evaporation Rate & Reference:11(ETHER=1)
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS LIQUID WITH A SOUR, PUNGENT ODOR
RESEMBLING VINEGAR
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, HYDROXIDES, AMINES, OXDIES, CARBONATES. AVOID
CONTAM W/ACETALDEHYDE, CHROMIC ACID & ALKALIES.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:WE WOULD EXPECT BURNING TO PRODUCE
CARBON MONOXIDE AND/OR CARBON DIOXIDE.

Disposal

Waste Disposal Methods:TRTMT/DISP WASTE GENERATED BY USE OF PROD SHOULD
BE REVIEWED IN TERMS OF APPLIC FED, ST & LOC LAWS & REGS. USERS ARE
ADVISED TO CONSULT W/APPROP REGULATORY AGENCIES BEFORE DISCHARGING,
TRTMT/DISPOSING OF MATL. WHERE PERMITTED UNDER ABOVE- (ING 4)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.